First of all, we should be daily, weekly, monthly check should maintain the injection molding machine manipulator, if one of the components have fault, it could cause the injection molding machine is not normal phenomenon, and wire connection problems, there is a little carelessness, coupled with large volume injection molding machine, in the absence of constant injection workshop under the conditions of use, the influence of the environment is easy to cause failure, found the problem in a timely manner to deal with, so that we can effectively prolong the life of our machine

One. Injection molding machine manipulator daily maintenance methods/steps

1. Wipe the guide rail for lubrication;

2. Filter and reduce pressure valve drainage;

3. Check the pressure of the air pressure source and the dryness of the air;

4. Check whether the negative pressure sensor is normal (if the product has not been sucked, whether it alarms)

5. The fixture detects whether the magnetic ring switch is normal (whether the product or handle is not clamped to the alarm).

6. Whether the interlock between the manipulator and the injection molding machine is normal (whether the manipulator does not lock the mold of the injection molding machine in the manual state and gives an alarm).

Two. Injection molding machine manipulator weekly maintenance methods/steps

1. Wipe the guide rail for lubrication

2. Filter and reduce pressure valve drainage

3. Check the pressure source and dryness of the air

4. Check whether the negative pressure sensor is normal (if the product has not been sucked, whether it alarms)

5. The fixture detects whether the magnetic ring switch is normal (whether the product or handle is not clamped to the alarm).

6. Whether the interlock of the injection molding machine of the special manipulator of the injection molding machine is normal (whether the injection molding machine of the special manipulator of the injection molding machine does not lock the mold and alarms in the manual state)

7. Check whether the connection bolts between the special manipulator of the injection molding machine and the injection molding machine are locked or loose

8. Check whether the setting bolts of each stroke control block are locked or loose.

Three. Injection molding machine manipulator monthly maintenance methods/steps

1. Check whether the tightness of the synchronization belt is appropriate

2. Clean filter pressure reducing valve and silencer

3. Readjust the running speed of each action

4. Check whether the negative pressure sensor is normal (if the product has not been sucked, whether it alarms)

5. The fixture detects whether the magnetic ring switch is normal (whether the product or handle is not clamped to the alarm).

6. Whether the interlock between the manipulator and the injection molding machine is normal (whether the manipulator does not lock the mold of the injection molding machine and gives an alarm in the manual state)

7. Check whether the bolts of all moving parts are fastened or loose

8. Determine if the pipeline is broken or if the wiring is loose or loose

9. Wipe the dust and oil on the arm of the special manipulator for injection molding machine to ensure that the special manipulator for injection molding machine is clean

10. Wipe the slide track of the special manipulator for injection molding machine, and add new lubricating oil

11. Check the inside of the electric control box