Common mechanical failure of injection molding machine and its solution
Release time: 2020-09-10 14:58:21  Hits: 50

The manipulator of injection molding machine will inevitably have some small problems in the long use process, when the machine has problems, how should we deal with it correctly?The following by the Rui Bo automation technology Co., Ltd. after sales engineer Zhou Sheng for everyone in view of the injection molding machine manipulator in the process of use of common problems to summarize and plan, teach you easy to quickly deal with the injection molding machine manipulator after the failure of the problem.

Failure 1: The injection molding machine does not lock the mold when using the manipulator.Check for suspects:

1: The motor of the injection molding machine is not on.

2: The pressure gauge does not respond and does not output when the injection molding machine presses the clamping mode.

3: Manipulator signal is not in place.

Treatment method:

1: Start the motor, but also can't lock the mold according to the following method.

Common mechanical failure of injection molding machine and its solution

2: When the pressure gauge of the injection molding machine has no pressure, the clamping signal of the injection molding machine plate is not output.When there is pressure, then determine the injection molding machine alone when the clamping mode is normal according to the following methods.

3: open inside the injection molding machine manipulator function, determine the manipulator can back to the origin of standby, manipulator signal lines to use the interface, and then confirm the manipulator clamping signals on the manual device, exit signals, mould the signal, are output, {switch next door, according to the mould opening to the end, the die cut of the switch again next door can confirm}, above all after repair also not line, injection molding machine is connected to the system of manipulator clamping signal lines out of the question.

Fault 2: The manipulator is normally taken out, but the injection molding machine is not fully automatic, and the alarm manipulator fails.

Treatment method:

1. The program of manipulator is not edited "allow injection molding machine mold" or the program is wrong;

2. The recycling time of injection molding machine is not enough, the recycling signal of injection molding machine or manipulator is not output.

Failure 3: manipulator can't return to the origin.

Treatment method:

1. Confirm whether the signals of several sensors in standby state are normal or the parameters of the operator are not set well.

2. Low air pressure.

Failure 4: Operator not displayed.

Treatment method:

1. Bad IC contact inside, bad display of operator.

2. Abnormal 24V power input of the operator.

Failure 5: Operator cannot set parameters

Treatment method:

Make sure that the set safety position parameter does not exceed the limit parameter (for example, if the horizontal limit parameter is 1300, the configuration parameter cannot be set above 1300).